Fluke 115 Digital Multimeter for Technicians

The 115 digital multimeter is for electrical and electronic testing in field service, industrial, and applications were more than the basic functions are needed.

  • Ideal for quick verifications and field service
  • Min/Max/Average to record signal fluctuations
  • CAT III 600V

Contact for price

Add to Wishlist
Add to Wishlist

Description

DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A overload for 30-seconds max
DC amps Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2 Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.
General Specifications
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10℃ to + 50℃
Storage temperature -40℃ to + 60℃
Battery type 9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g

Reviews

There are no reviews yet.

Be the first to review “Fluke 115 Digital Multimeter for Technicians”

Your email address will not be published. Required fields are marked *