MIT515 – 5 kV insulation tester Megger

 

  • Insulation resistance up to 30 TΩ @ 15 kV, 20 TΩ @ 10kV, 10 TΩ @ 5 kV
  • IR, Timed IR, DAR, PI, DD, SV and Ramp diagnostic tests
  • High current – 3 mA short circuit current
  • High noise immunity – 3 mA (5 kV and 10 kV) 6 mA (15 kV) of noise rejection
  • Li-ion battery – up to 6 hrs continuous testing @ 5 kV with a 100M load, battery meets IEC 2133
  • Safety rating: CAT IV 600 V to 3000 m (5 kV, 10 kV) CAT IV 1000 V to 3000 m (15 kV)
  • Large LCD with backlight
  • Dedicated voltmeter function (30 V to 660 V)
  • MIT515, MIT525 and MIT1025 safety rated at CAT IV 600 V (maintained to 3000 m altitude)
    a.c. voltage (auto-ranging) 90-264 V rms, 47- 63 Hz 100 VA
    Battery Charge Time 2.5 hours deep discharge, 2 hours normal discharge
    Battery life 1.1 V, 5.2Ah Li-ion batteries, meet IEC 62133:2003, MIT1525 has 2 battery packs
    6 hours (typical) continuous testing at 5 kV with a 100 MΩ load
    Test Voltage 250 V, 500 V, 1000 V, 2500 V, 5000 V, VL
    Lock test voltage 100 VL to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps
    Test voltage accuracy +4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0°C to 30°C)
    Resistance range 10 kΩ to 15 TΩ @ 5 kV, 10 kΩ to 20 TΩ @ 10 kV, 10 kΩ to 30 TΩ @ 15 kV
    Accuracy 5000 V 2500 V 1000 V 500 V 250 V
    ±5% from 1MΩ to
    1 TΩ 500 GΩ 200 GΩ 100 GΩ 50 GΩ
    ±20% from 1MΩ to
    10 TΩ 5 TΩ 2 TΩ 1 TΩ 500 GΩ
    Guard terminal performance Guards out parallel leakage resistance down to 250 kΩ with a maximum additional resistance error of 1% with a 100 MΩ load
    Display analog: 100 kΩ to 10 TΩ
    Digital: 10 kΩ to max. a above
    Short circuit / charge current 3 mA @ 5 kV, 10 kV, 15 kV
    Insulation test alarm: 100 kΩ to 10 GΩ
    Capacitor charge <3 s/μF at 3 mA to 5 kV
    Capacitor discharge <120 ms/μF to discharge from 5000 V to 50 V
    Capacitance range
    With test voltage set above 500 V
    0 nF to 25 μF
    Capacitance measurement accuracy ±10% ±5 nF
    Current range 0.01 nA to 6 mA
    Current accuracy ±5% ±0.2 nA at all voltages (23 °C)
    Interference 3 mA from 450 V to 5 kV
    Voltmeter range 30 V to 660 V a.c. or d.c., 45Hz – 65Hz
    Voltmeter accuracy ±3%, ±3V
    Timer range Up to 99 minutes 59 seconds, 15 second minimum setting
    Memory capacity 5.5 hours logging @ 5 sec intervals
    Test modes IR, IR(t), DAR, PI
    Interface USB type B (device)
    Real time output 1 Hz output readings (V, I, R)
    ENVIRONMENTAL
    Maximum altitude 3000 m
    Operating temperature range -4 °F to +122 °F (-20 °C to +50 °C)
    Storage temperature range -13 °F to +149 °F (-25 °C to +65 °C)
    Humidity 90% RH non-condensing at 104 °F (40 °C)
    IP rating IP65 (lid closed), IP40 (lid open)
    Safety CAT IV 600 V to 3000 m altitude

    For full Megger MIT515 Insulation Tester product specifications, please click here: Megger MIT515

Add to Wishlist
Add to Wishlist

Description

a.c. voltage (auto-ranging) 90-264 V rms, 47- 63 Hz 100 VA
Battery Charge Time 2.5 hours deep discharge, 2 hours normal discharge
Battery life 1.1 V, 5.2Ah Li-ion batteries, meet IEC 62133:2003, MIT1525 has 2 battery packs
6 hours (typical) continuous testing at 5 kV with a 100 MΩ load
Test Voltage 250 V, 500 V, 1000 V, 2500 V, 5000 V, VL
Lock test voltage 100 VL to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps
Test voltage accuracy +4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0°C to 30°C)
Resistance range 10 kΩ to 15 TΩ @ 5 kV, 10 kΩ to 20 TΩ @ 10 kV, 10 kΩ to 30 TΩ @ 15 kV
Accuracy 5000 V 2500 V 1000 V 500 V 250 V
±5% from 1MΩ to
1 TΩ 500 GΩ 200 GΩ 100 GΩ 50 GΩ
±20% from 1MΩ to
10 TΩ 5 TΩ 2 TΩ 1 TΩ 500 GΩ
Guard terminal performance Guards out parallel leakage resistance down to 250 kΩ with a maximum additional resistance error of 1% with a 100 MΩ load
Display analog: 100 kΩ to 10 TΩ
Digital: 10 kΩ to max. a above
Short circuit / charge current 3 mA @ 5 kV, 10 kV, 15 kV
Insulation test alarm: 100 kΩ to 10 GΩ
Capacitor charge <3 s/μF at 3 mA to 5 kV
Capacitor discharge <120 ms/μF to discharge from 5000 V to 50 V
Capacitance range
With test voltage set above 500 V
0 nF to 25 μF
Capacitance measurement accuracy ±10% ±5 nF
Current range 0.01 nA to 6 mA
Current accuracy ±5% ±0.2 nA at all voltages (23 °C)
Interference 3 mA from 450 V to 5 kV
Voltmeter range 30 V to 660 V a.c. or d.c., 45Hz – 65Hz
Voltmeter accuracy ±3%, ±3V
Timer range Up to 99 minutes 59 seconds, 15 second minimum setting
Memory capacity 5.5 hours logging @ 5 sec intervals
Test modes IR, IR(t), DAR, PI
Interface USB type B (device)
Real time output 1 Hz output readings (V, I, R)
ENVIRONMENTAL
Maximum altitude 3000 m
Operating temperature range -4 °F to +122 °F (-20 °C to +50 °C)
Storage temperature range -13 °F to +149 °F (-25 °C to +65 °C)
Humidity 90% RH non-condensing at 104 °F (40 °C)
IP rating IP65 (lid closed), IP40 (lid open)
Safety CAT IV 600 V to 3000 m altitude

 

Reviews

There are no reviews yet.

Be the first to review “MIT515 – 5 kV insulation tester Megger”